Basic Info.
Material
Stainless Steelor FRP or Iron
Flow Direction
Axial Flow
Cooling Method
Direct Cooling
Rotational Speed (R/Min)
720~2900
Electric Voltage
220V-380V-440V
Transport Package
Plywood Box with Steel Frame, Sea Worthy Packing
Specification
ISO9001 ISO14001
Product Description
Stainless Steel FRP Anticorrosion Axial Fan Blowers for Factory
T35-11 Axial-flow blower is a kind of ventilators with high efficiency and low pressure which the engine committee recommend to use. In addition to the same functions as the congener metal ventilators, the blower has virtues of light\low noise\well run\high efficiency and anticorrosion.
This kind of products can be used not only in chemical plant\machine building\printing and dyeing\electroplating\paper making\food processing etc fields but also in theaters\hotels\offices and other dwelling houses to let fresh air in and stale air out. If take off the shelf, it can be used as free fan or used as a part of a vent-pipe to increase the wind pressure in the pipeline.
ST35-11 blower is equipped with apiece-pole electromotor joined with impeller directly. The engine casing is columnar; The direction of rotation is clockwise. According to the impeller's diameter this kind of blower can be classified into thirteen types from NO2.8 to NO11.2. The four vanes can be assembled 15\20\25\30\35 five species angle. Because of the different angle of impellers assembling and the different rev of principal axis, the wind pressure\air quantity and power are different.
DIRECTIONS OF FIX AND USE
A\Connecting type should be taken into account when the blower is connected with pipeline to reduce the loss of dynamic pressure. The diffuser cannot be equipped if the diameter of pipeline is less than one point five times wind tuner's diameter, yet the length of the pipeline is shorter than five to eight times of the pipe's dia. Otherwise the diffuser should be equipped. (picture one below) If used in longer pipeline the blower can be fixed in series to increase the wind pressure, but the distance between the two blowers should not be too far. (picture two below)
B\We must check parts carefully to find whether they are damaged, whether there are friction between impeller and other parts, whether the clearance between the vane and intake before fixing.
C\The weight of the pipe connected with uptake should be supported separately not supported by wind tuner.
D\Collective ventilator and wire netting should be fixed in the side of the Arial's intake.
E\The base of blower and the groundsill should be smooth. When fixing the blower should be kept in horizontal position, then tighten the screws.
F\This kind blower can't be hoisted. After fixing, we should test run the blower.
G\We should check the pontes of the blower if we use it after a long time' stoppage.
H\We should check whether the screw is loosen, whether the wire coat is damaged and repair.
I\Pay attention to whether there is unwonted noise when the blower is running and repair in time.
Advantage | high efficiency low pressure light weight well run anticorrosion |
Application | chemical plant machine building printing and dyeing electroplating paper making food processing theaters hotels other dwelling houses offices
If take off the shelf, it can be used as free fan or used as a part of a vent-pipe to increase the wind pressure in the pipeline |
Direction of rotation | Clockwise |
Vanes angle | 15, 20, 25, 30, 35 degree |
Axial Flow Blower
1.Application:
ZHT35-11 axial flow blower is mainly used for the air change and strength the heating radiator in factory, warehouse, office, residence and other situations. Also it can install in the exhaust pipe with long interval series to improve the air pressure in the pipeline.
2. Model
(1) This series products can be divided into 13 device number according to the impeller diameter: No.2.8, 3.15, 4, 4.5, 5, 5.6, 6.3, 7.1, 8, 9, 10, 11.2. Each model can be installed into 15°,20°,25°,30°and 35°five kind angles
(2) This series product adopts to the straight league structure which the impeller is installed on the motor shaft directly. There are three rotated speeds: 2900 r/min, 1450 r/min and 960 r/min. The rotation direction is clockwise(observation by the motor direction.) Before delivery, all of fans should be tested to guarantee the operation smooth.
3. The Structure:
This kind of axial flow blower is mainly composed by three parts such as impeller, casing and air collection device.
(1) Impeller: composed by blade and wheel hub. The material of blade is sheet steel, it is welded on the wheel hub according to the selected installation angle.
(2) Sheel: composed by air duct and support. The material is sheet steel. The air duct is cylindrical and there is a certain gap between the impeller.
(3) Air Collection Device: composed by the flange and air collection device. The material is sheet steel and it is arc streamlined to reduce the the loss of air inlet.
4. Technique Parameter:
Model No. | Speed | Total pressure | Air volume | Motor power |
R/min | Pa | m³/h | KW |
2.8 | 2900 | 148 | 2662 | 0.18 |
1450 | 37 | 1331 | 0.025 |
3.15 | 2900 | 188 | 3790 | 0.37 |
1450 | 47 | 1895 | 0.04 |
3.55 | 2900 | 240 | 5424 | 0.55 |
1450 | 60 | 2712 | 0.09 |
4 | 2900 | 304 | 7758 | 1.10 |
1450 | 76 | 3879 | 0.18 |
4.5 | 1450 | 96 | 5524 | 0.25 |
5 | 1450 | 119 | 7577 | 0.37 |
960 | 47 | 5104 | 0.18 |
5.6 | 1450 | 149 | 10645 | 0.75 |
960 | 59 | 7171 | 0.37 |
6.3 | 1450 | 189 | 15157 | 1.5 |
960 | 75 | 10210 | 0.37 |
7.1 | 1450 | 240 | 21695 | 2.2 |
960 | 95 | 14614 | 0.75 |
8.0 | 1450 | 305 | 31035 | 4.0 |
960 | 120 | 20906 | 1.1 |
9.0 | 960 | 152 | 29767 | 2.2 |
10.0 | 960 | 188 | 40832 | 4.0 |
11.2 | 960 | 236 | 57366 | 5.5 |
5. The Appearance and installation dimension
Model | A | B | C | D | E | F | G | H | I | J | K | n | φd1 | φd2 | kgs |
2.8 3.15 3.55 4 4.5 5 5.6 6.3 7.1 8 9 10 11.2 | 283 316 358 404 454 504 564 634 715 805 905 1006 1126 | 320 355 385 450 500 560 620 690 770 860 970 1070 1190 | 346 381 422 478 528 588 649 719 800 891 1001 1103 1223 | 355 400 450 500 580 630 710 800 900 1000 1120 1250 1400 | 220 240 280 300 260 300 330 390 400 480 540 630 700 | 258 282 327 349 314 364 404 474 494 579 648 753 888 | 212 232 272 292 252 290 318 378 388 468 526 616 686 | 220 240 260 290 330 340 390 440 490 550 610 670 760 | 100 220 210 280 310 410 440 440 630 700 810 800 1080 | 175 190 230 240 205 240 260 320 330 380 440 505 580 | 260 300 320 370 430 430 490 540 700 770 850 956 1289 | 4 8 8 8 8 12 12 12 16 16 16 16 20 | 10 10 10 12 12 12 12 12 12 12 15 15 15 | 12 12 12 12 12 12 14 14 14 18 18 22 22 | 10.26 13.20 14.28 21.03 22.93 30.96 41.34 57.56 87.82 90.87 121.18 151.16 192.10 |
6.Installation and Maintain
Installation:
1.Before installation, the blower should be carefully checked whether the deformation due to package or shipping damage before installation. If damaged, it should be repaired before installation.
2. It should be checked the connection part of the loose leaves when installation Installation and duct clearance should be uniform, not scratching.
3, The weight which connecting the outlet of the pipeline should not be bear by the fan duct. It should plus the support when installation.
4, The fan base must be spontaneous combination with the ground plane and must not force the connection.
5 After installation, you must first be tested to be operating normally before official use.
Maintain:
1.The air through the blower must be clean and dry.not mixed with impurities and excessive water vapor;
2, fans are not allowed to lifting, re-use in long idle connections must be checked whether the part of the solid and reliable rotation is flexible and after commissioning before official use;
3, always pay attention to the fan in operation without abnormal sound, vibration is increased, found irregularities, should be timely maintenance
Address:
No. C Internatonal Business Center, Environmental Technology Park, High-Tech Zone, Jinan City, Shandong, China
Business Type:
Manufacturer/Factory
Business Range:
Chemicals, Construction & Decoration, Industrial Equipment & Components, Manufacturing & Processing Machinery, Service, Transportation
Management System Certification:
ISO 9001, ISO 14001
Company Introduction:
Jinan Shuangyi Environment Engineering Co., Ltd. (Shunagyi) integrates science and technology, engineering and trade together. Our main products are cooling towers, FRP products, blowers, water tanks, ventilators, ventilator pipelines, fireproofing valves, fume extract valves, lab facilities, fans, FRP lab facilities, medicine lockers, vessel lockers, reagent storage racks, enwind pipes, enwind tanks, FRP pipes, FRP tanks, FRP retainers, FRP pantiles, daylighting covers, rotproof facilities, bodyworks, auto-coverings, auto fittings, battery cars, mobile machinery shop fittings, engine room covers, hubcaps, air deflectors, architectural decorate materials, pultrusion-wood, furniture, SMC products, RTM products, garbage bins, textile machinery, air conditioning units, air-conditioners, wind screen machines, central air-conditioning and engineering machines and composite materials.
Our company has advanced equipment and we are honored as "Provincial Contract Trustworthy Enterprise" by Shandong Province Government. We have passed the authentication of Switzerland SGS, ISO9001 International Quality System and ISO14001 Environmental Management System certifications.
We boast solid capital strength, superb technology and advanced management, and we always abide by the principle of "based on the market, winning with quality, innovation and development". We continue to develop and hope to establish a new corporate image.
We have 7 subsidiary companies (branches) and an FRP Institute, such as Dezhou FRP Plant, Shuangyi Cooling Tower Limited, Shuangyi Fan Limited, Shuangyi Refrigeration Installation Limited, Yaxing Textile Machinery Manufacturing Co., Ltd. And Meihua (Dezhou) Industrial Company Limited. Dezhou FRP Plant is our core subsidiary, famous for early foundation (set up factories in 1984), large-scale, and precise products in our country.
Facing challenges in the 21st century, Shuangyi can continue to seize the opportunity of China′s entry into WTO and promote our spirit of "unity, truth-seeking, high-quality and innovative". With new corporate image and superior product quality, we strive to create a brilliant future.